Enter a search term and click .

Projector control

It's possible to control the projector by sending commands through the control channel or LAN.

bTIP

Use FUJIFILM PROJECTOR CONTROLLER for projector control via the control channel or LAN. FUJIFILM PROJECTOR CONTROLLER is available for download from the sites below.

https://global.fujifilm.com/en/business-optical-devices/projector/fpz8000

  • When this software is used with FP-Z8000, the firmware version of FP-Z8000 should be 1.06 or later.
  • FP-Z5000 is not supported.
  • FP-Z6000 is compatible with Fujifilm projector controllers in all firmware versions.

System condition

Control channel

Item RS-232C HDBaseT LAN
Connection cable Dsub9 RJ45 (Category 5e or above) RJ45
Communication mode RS-232C Asynchronous , Half-duplex communication TCP: Port23
Baud Rate 115200 9600
Data Length 8 bit
Parity Check None
Stop Bit 1 bit
Flow Control None

Control command

Power

Read/Write Operation Command (ASCII) Remark
Write Power On POWER=ON<CR> It is effective in the standby state.
Write Power Off POWER=OFF<CR>
Read Power Status GET=POWER<CR> In the case of RS-232C control, It is effective in any power state. In the case of LAN control, It is effective only when the projector is turned on. [Warming Up] POWER=OFF2ON [Cooling Down] POWER=ON2OFF

Source Selection

Read/Write Operation Command (ASCII) Remark
Write HDMI1 INPUT=HDMI1<CR>
Write HDMI2 INPUT=HDMI2<CR>
Write Display Port INPUT=DISPLAYPORT<CR>
Write HDBaseT INPUT=HDBASET<CR>
Write SDI INPUT=SDI<CR>
Read Current source GET=INPUT<CR>

Audio Control

Read/Write Operation Command (ASCII) Remark
Write Mute On MUTE=ON<CR>
Write Mute Off MUTE=OFF<CR>
Read Mute Status GET=MUTE<CR>
Write Volume + RC=VOL_P<CR>
Write Volume - RC=VOL_M<CR>
Read Volume Status GET=AVOL<CR>

Picture Mode

Read/Write Operation Command (ASCII) Remark
Write Bright PICTURE=BRIGHT<CR> It is effective when there is a video input.
Write Standard PICTURE=STANDARD<CR>
Write sRGB PICTURE=SRGB<CR>
Write DICOM PICTURE=DICOM<CR>
Read Picture Mode GET=PICTURE<CR>
Write Aspect 4:3 ASPECT=4:3<CR>
Write Aspect 16:9 ASPECT=16:9<CR>
Write Aspect Auto ASPECT=AUTO<CR>
Write Aspect Real ASPECT=REAL<CR>
Write Aspect 16:10 ASPECT=16:10<CR>
Read Aspect Status GET=ASPECT<CR>

Operation Settings

Read/Write Operation Command (ASCII) Remark
Write Front Table PROJECTION=NONE<CR>
Write Rear Table PROJECTION=REAR<CR>
Write Front Ceiling PROJECTION= CEILING<CR>
Write Rear Ceiling PROJECTION= REAR_CEIL<CR>
Read PROJECTION Status GET=PROJECTION<CR>
Write Quick Auto search QAS=ON<CR>
Write Quick Auto search QAS=OFF<CR>
Read Quick Auto search status GET=QAS<CR>

Control

Read/Write Operation Command (ASCII) Remark
Read LIGHT Hour GET=PJUSGT<CR>
Write LIGHT Mode Normal LIGHT=NORMAL<CR>
Write LIGHT Mode Economic LIGHT=ECO<CR>
Read LIGHT Mode Status GET=LIGHT<CR>
Write Freeze On FREEZE=ON<CR> It is effective when there is a video input.
Write Freeze Off FREEZE=OFF<CR>
Read Freeze Status GET=FREEZE<CR>
Write Menu On MENU=ON<CR>
Write Menu Off MENU=OFF<CR>
Write BACK RC=BACK<CR>
Write Up RC=UP<CR>
Write Down RC=DOWN<CR>
Write Right RC=RIGHT<CR>
Write Left RC=LEFT<CR>
Write ENTER RC=ENTER<CR>
Write Stop lens operation RC=STOP<CR> When FOCUS1 / 2, zoom, and lens shift move, this command can stop the lens operation.
It can be used with the firmware version 1.06 or later.
Write High Altitude mode On HIGHALT=ON<CR>
Write High Altitude mode Off HIGHALT=OFF<CR>
Read High Altitude mode status GET=HIGHALT<CR>
Read Temperature T1 query GET=TEMP1<CR>
Read Temperature T2 query GET=TEMP2<CR>
Read Error log 1 query GET=ERRLOG1<CR>
Read Error log 2 query GET=ERRLOG2<CR>
Read Error log 3 query GET=ERRLOG3<CR>
Read Error log 4 query GET=ERRLOG4<CR>
Read Error log 5 query GET=ERRLOG5<CR>
Read Error log 6 query GET=ERRLOG6<CR>
Read Error log 7 query GET=ERRLOG7<CR>
Read Error log 8 query GET=ERRLOG8<CR>
Read Error log 9 query GET=ERRLOG9<CR>
Read Error log 10 query GET=ERRLOG10<CR>
Read Error log 11 query GET=ERRLOG11<CR>
Read Error log 12 query GET=ERRLOG12<CR>
Read Error log 13 query GET=ERRLOG13<CR>
Read Error log 14 query GET=ERRLOG14<CR>
Read Error log 15 query GET=ERRLOG15<CR>
Read Error log 16 query GET=ERRLOG16<CR>
Read Error log 17 query GET=ERRLOG17<CR>
Read Error log 18 query GET=ERRLOG18<CR>
Read Error log 19 query GET=ERRLOG19<CR>
Read Error log 20 query GET=ERRLOG20<CR>
Read FAN1 rotation speed query GET=FANSPD1<CR>
Read FAN2 rotation speed query GET=FANSPD2<CR>
Read FAN3 rotation speed query GET=FANSPD3<CR>
Read FAN4 rotation speed query GET=FANSPD4<CR>
Read FAN5 rotation speed query GET=FANSPD5<CR>
Read FAN6 rotation speed query GET=FANSPD6<CR>
Read FAN7 rotation speed query GET=FANSPD7<CR>
Read FAN8 rotation speed query GET=FANSPD8<CR>
Read FAN9 rotation speed query GET=FANSPD9<CR>
Read FAN10 rotation speed query GET=FANSPD10<CR>
Read FAN1 target rotation number query GET=FANTG1<CR>
Read FAN2 target rotation number query GET=FANTG2<CR>
Read FAN3 target rotation number query GET=FANTG3<CR>
Read FAN4 target rotation number query GET=FANTG4<CR>
Read FAN5 target rotation number query GET=FANTG5<CR>
Read FAN6 target rotation number query GET=FANTG6<CR>
Read FAN7 target rotation number query GET=FANTG7<CR>
Read FAN8 target rotation number query GET=FANTG8<CR>
Read FAN9 target rotation number query GET=FANTG9<CR>
Read FAN10 target rotation number query GET=FANTG10<CR>
Read LED indicator query GET=LEDIND<CR> LEDIND=ON/STANDBY,TEMP,STATUS<CR> Example: LEDIND=4,0,0<CR> (power on)
LED Status Value
LED_Off 0
LED_R_ON 1
LED_R Flash 0.4sec 2
LED_R Flash  1 sec 3
LED_G ON 4
LED_G Flash 0.4sec 5
LED_G Flash  1 sec 6
LED_R and LED_G ON 7
LED_R and LED_G Flash 0.4sec 8
Read DDP S/W version query GET=VER_DDP<CR>
Read LAN S/W version query GET=VER_LAN<CR>

Software specification

  1. If the data is send but didn’t send <CR> to finish the command in 5 seconds, it will timeout and need to resend command.
  2. If the command format is illegal, it will echo “Illegal format”.
  3. If the command format is correct, but it is not valid for this model, it will echo “Unsupported item”.
  4. If the command format is correct, but can’t be execute in some condition, it will echo “Block item”.
  5. Command interval need 2 – 3 sec during Lan standby

    bTIPS

    • In low power, full power standby, warming up and cooling down if the command can’t execute, it will always return “Block item”.
    • No case sensitive.
    • If you turn the projector off after changing the IP address, the new settings will be reflected in the display 30 seconds after you next turn the projector on.
    • It takes about 60 seconds to accept commands after turning on the power.
  6. If using control commands to change aspect ratio, it will also close OSD menu.

dCAUTIONS

  • For power operation via serial communication, the command needs to be sent twice.
  • The command interval requires about 2 to 3 seconds for serial communication.